Home /

Three Phase Power Quality Analyzer Data Logger , Power Harmonics Analyzer 120

Send your message to this supplier
*From:
Your email address is incorrect!
To:Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Yes!I would like your verified suppliers matching service!
Buy cheap Three Phase Power Quality Analyzer Data Logger , Power Harmonics Analyzer 120-400V from wholesalers
  • Buy cheap Three Phase Power Quality Analyzer Data Logger , Power Harmonics Analyzer 120-400V from wholesalers
  • Buy cheap Three Phase Power Quality Analyzer Data Logger , Power Harmonics Analyzer 120-400V from wholesalers
  • Buy cheap Three Phase Power Quality Analyzer Data Logger , Power Harmonics Analyzer 120-400V from wholesalers

Three Phase Power Quality Analyzer Data Logger , Power Harmonics Analyzer 120-400V

Ask Latest Price
Brand Name:GFUVE
Model Number:E6000
Certification:CE
Price:Negotiable
Company Data
Verified Supplier
Contact Person Andy
Business Type: 86-10-85782698
Business Type: Manufacturer
Officials: Oriental HuaRui A, No. 150 Guanzhuang Road, Chaoyang District, Beijing, 100024, China
Quality: Quality Certifitation Available
Product Details Company Profile
Product Details

Handheld Three Phase Power Quality And Energy Analyzer


E6000 handheld three phase power quality analyzer with CT offer the best ability in power quality analysis, E6000 handheld power quality analyzer help locate, predict, prevent and troubleshoot power quality problems in three phase and single phase power distribution systems. Additionally, GFUVE patented energy loss algorithm, unified power measurement, measuring and counting energy losses due to harmonics and unbalance issues, allowing the user to pinpoint the origin of energy losses in the system.


FEATURES


  • 3s statistical interval, continuously record 120h;
  • Support multi-brand current transformer;
  • Up to 8G data storage space;
  • Record up to 461 power energy parameters simultaneously;
  • Up to 6500 screenshots saved;
  • Support periodic recording function;
  • Up to 3.9M/s USB high-speed transfer;
  • Customized international report generation.

Electrical parameters 
Voltagerms, ava, pk+, pk-, rms-1/2, CF
FrequencyFreq
Currentrms, ava, pk+, pk-, rms-1/2, CF
Power & energyP, S, Q, PF, DPF, W
ComputationTHD, DC, 1-50 Harm, 1-50 InHarm, 1-35 HiHarm, 1-50 SubHarm
Voltage harmonicTHD, DC, 1-50 Harm, 0-49 InHarm, 1-35 HiHarm, 1-50 SubHarm , KF
Current harmonicTHD, DC, 1-50 Harm
Harmonic powerIa, Ib, Ic, ΣPtotal, ΣQtotal, ΣStotal, 15 minutes
Fluctuation and flickeringPST, PLT, Fluct, Fluct Max
UnbalV Pos, A pos , V neg , A neg , V zero, A zero, Unbal
Event logVoltage swell, voltage sags, DIP, surge current, voltage and current distortion out of limit, odd harmonics containing rate out of limited, unbalanced voltage current out of limit, frequency out of limit, PST out of limit, PLT out of limit, long-term voltage interruption, voltage fluctuation deviation
P, Q, S name 
Measurement typesP: Calculate by every 10 cycles
S: Calculated by the effective value of voltage and current
Q: Calculated by the apparent power, active power
DisplayTable charts, trend chart
Measuring range/resolutionAccording to the range of the voltage and current
measuring accuracy±0.5%
Arms 
Measurement modeCalculated by the square root value of 10 cycle
Display modeEffective current value of each channel
Measuring range/resolutionCurrent: according to the current clamps
Option:5A/50A/100A/500A
Current clamps: 1200A/3000A/6000A(Flexible Current Clamp)
Accuracy0.1% + accuracy of the current clamps
Frequency 
Measurement modeCalculate by 10 cycles (50Hz) or (60Hz)
Display modeMeasurement by 10 cycles
Nominal frequency/resolution50.000Hz/0.001Hz or 60.000Hz/0.001Hz
Bandwidth measurement42.5-57.5Hz or 52.5-67.5Hz
Measurement accuracy±0.001Hz
Half-wave RMS current/voltage 
Measurement modeCalculate by every 2 cycles. Each cycle ,1/2 cycle made up of a waveform calculation
Measuring range/resolutionVoltage: 120V/0.01V, 230V/0.01V, 400V/0.01V, 1000V/0.01V,Current: According to the current clamps
measurement accuracy±0.1%
Vrms 
Measuring circuit1P2W/ 2P3W /3P3W/ 3P4W
Basic frequency of the measuring circuit50Hz
Input channels4 phase voltage, 4 phase current
Measurement rangeVoltage measurement range: standard: 120V, 230V, 400V, 1000V, Max 1000V instantaneous voltage
Current measurement range: according to the current clamps, only support the v signal output current clamp
Power factor 
Measurement modeThe ratio of average power to apparent power
Display modeReal-time data showed
Measurement range/resolution-1.000-1.000/0.001
Measurement accuracy±1%
Vfund, Afund, Harmonic power 
Measurement modeMeet IEC61000-4-7,Analysis time window is ten cycles
Window points5120 points
Display modeForm figure, trend charts, histograms
Number of measurement1-50 Times
Measurement accuracyVfund >1%: Error<1%
Vfund <1%: Error<0.05% Rated Voltage
Afund >3%: Error<1%
Afund <3%: Error<0.05% Current range
InHarm Voltage, InHarm current 
Measurement modeMeet IEC61000-4-7, Analysis time window is ten cycles
Window points5120 points
Display modeForm figure, trend charts, histograms
Numbers of measurement1-16 groups
Measurement accuracyVfund >1%: Error<1%
Vfund <1%: Error<0.05% Rated Voltage
Afund >3%: Error<1%
Afund <3%: Error<0.05% Current range
HiHarm Voltage, HiHarm current 
Measurement modeMeet IEC61000-4-7, Analysis time window is ten cycles
Window points5120 points every 10 cycles
Display modeForm figure, trend charts, histograms
Numbers of measurement1-35 groups
Measurement accuracyVfund >1%: Error<1%
Vfund <1%: Error<0.05% rated voltage
Afund >3%: Error<1%
Afund <3%: Error<0.05% current range
Voltage SubHarm Current SubHarm 
Measurement modeMeet IEC61000-4-7, analysis time window is ten cycles
Window points5120 points every 10 cycles
Display modeForm figure, trend charts, histograms
Numbers of measurement1-50 groups
Measurement accuracyVfund >1%: Error<1%
Vfund <1%: Error<0.05% Rated Voltage
Afund >3%: Error<1%
Afund <3%: Error<0.05% Current range
Voltage/current Unbal (pos, neg) 
Measurement mode3P3W or 3P4W, using three phase of fundamental wave components to calculate
Display modeForm figure, trend charts, histograms
Measurement accuracyVoltage unbal: ±0.2%
Current unbal: ±0.5%
Voltage fluctuation 
Measurement modeCalculate by the quadratic mean of half wave.
Display modeForm figure, trend charts
Measurement accuracy±1%
IEC Flickering 
MeasurementP short term (Pst) , P long term (Plt)
Measurement modeAccording to IEC61000-4-15 Standard to calculate Pst (10 mins) Plt (2 hours)
Display modeForm figure, trend charts
Measurement range0-20
Measurement accuracy±5%
Surge current 
Measurement modeHalf-wave RMS of current is higher than set value and sustain time is 10ms-1min
Display modeMaximum of the surge current and surge current wave
Measurement accuracy0.10%
Voltage swell, Voltage sags, DIP 
Measurement modeSwell: When half-wave RMS of voltage is higher than set value and sustain time is 10ms-1min, judged as swell.
Sags: When half-wave RMS of voltage is lower than set value and sustain time is 10ms-1min, judged as sags.
DIP: half-wave RMS of voltage is higher than set value and sustain time is 10ms-1min, judged as DIP
Display modeSwell, sags, DIP wave sustain time, extent and so on.
Measurement accuracy0.10%
Machinery 
Size263mm x 168mm x 65mm
Weight2KG
Power supply 
Voltage input110V-240V
Adapter output15V, 3A
BatteryRechargeable nickel metal hydride, 4500mAh
Battery working time4h
Battery recharging time5h (Environment temperature 25°C)
Power saving facilityLCD backlight brightness is adjustable, standby time is adjustable
Display 
Size112.8 x 84.6mm
Color260000 color
Resolutions640 x 480
BrightnessMax 350 cd/m2 (Typ), brightness is adjustable
Contrast500:1 (Typ)
Visual angle70/70/50/70 (Typ.)(CR ≥10) ( Left/ Right/ UP/Down)
Store 
TypeTF card (inbuilt)
Size8G
Standards 
Measurement methodIEC 61000-4-30
Measurement performanceIEC 61000-4-30 A LVL
FlickeringIEC 61000-4-15
HarmonicIEC 61000-4-7
Safety 
StandardGB 4793.1-2007/IEC 61010-1:2001: "Measurement, control and laboratory electrical equipment safety requirements", first part: general requirements.
Security level: CAT III 1000 V/ CAT IV 600 V.
MAX voltage of phase angle inputCAT III 1000V/CAT IV 600V
Environmental conditions 
Working environment0°C to +45°C, humidity below 90rh%
Storing environment-20°C to +50°C, humidity below 95rh% (non-condensing)

Three Phase Power Quality Analyzer Data Logger , Power Harmonics Analyzer 120-400V

Company Profile

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

Beijing GFUVE Instrument Transformer Manufacturer Co., Ltd. was established in 2008. It combined design, manufacturing and sales together as one high-tech enterprise. GFUVE Instrument Transformer company mainly produces less than 35kV current transformer and voltage transformer, split core ct and current clamp models etc.

GFUVE is a leader manufacturer of split core current transformer products in China. It is professional in current transformer, potential transformer and related accessory. The product of outdoor split core current transformer develops very quickly in the global market. Our company has achieved certification to ISO9001. The products are sold to over 30 provinces in China and exported to overseas including South America, Middle East, Southeast Asia, Australia and Africa.

Please contact us now for further business relationship. We are here to provide you the best service and the best product.

Send your message to this supplier
*From:
Your email address is incorrect!
*To:

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Characters Remaining : (0/3000)

You May Like

China 3 Phase Power Quality Analyzer , Portable Power Analyzer Energy Loss Calculator wholesale

3 Phase Power Quality Analyzer , Portable Power Analyzer Energy Loss Calculator

China Harmonics Power Quality Analyser Rechargeable Battery Measuring Energy Consumption wholesale

Harmonics Power Quality Analyser Rechargeable Battery Measuring Energy Consumption

China Lightweight Power Quality Analyzer , 3 Phase Power Data Logger Crystal Big Screen wholesale

Lightweight Power Quality Analyzer , 3 Phase Power Data Logger Crystal Big Screen

China GFUVE GF334 Small Size Portable Power Quality Meter Ultra - Compact Design wholesale

GFUVE GF334 Small Size Portable Power Quality Meter Ultra - Compact Design

China Handheld Three Phase Power Quality Analyzer 0.1% Accuracy With 100A Current Clamp wholesale

Handheld Three Phase Power Quality Analyzer 0.1% Accuracy With 100A Current Clamp

China Class A Three Phase Power Quality Analyzer With Flicker 63rd Harmonics For Electric Motors Testing wholesale

Class A Three Phase Power Quality Analyzer With Flicker 63rd Harmonics For Electric Motors Testing

China High Accuracy Three Phase Power Analyzer / Portable Power Analyzer For Distribution wholesale

High Accuracy Three Phase Power Analyzer / Portable Power Analyzer For Distribution

China GFUVE Handheld Three Phase Power Quality Analyser High Precision 32G Memory wholesale

GFUVE Handheld Three Phase Power Quality Analyser High Precision 32G Memory

China IEC6100-4-30 Class A Power Quality Analyzer 0.001V Resolution High Accuracy wholesale

IEC6100-4-30 Class A Power Quality Analyzer 0.001V Resolution High Accuracy

China Small Volume Gf311 Portable Power Quality Meter With RS232 Communication Port wholesale

Small Volume Gf311 Portable Power Quality Meter With RS232 Communication Port

China Gf211b Double Channel Power Quality Analyser Phase Angle Meter With 3.7v Batteries wholesale

Gf211b Double Channel Power Quality Analyser Phase Angle Meter With 3.7v Batteries

Inquiry Cart 0